引用本文: | 南淑清,多克辛,赵秀荣,罗财红.铜试剂分光光度法测定丁基黄原酸方法的优化研究[J].环境监控与预警,2013,5(4):22-26 |
| NAN Shu qing,DUO Ke xin,ZHAO Xiu rong,LUO Cai hong.Optimization of Determination of Butyl Xanthate by Copper Reagent Spectrophotometric Method[J].Environmental Monitoring and Forewarning,2013,5(4):22-26 |
|
摘要: |
根据方法原理,调整分析步骤中试剂加入顺序进行方法优化。方法优化后,反应体系稳定性增强,检出限达到0001mg/L。 |
关键词: 丁基黄原酸 铜试剂分光光度法 方法优化 |
DOI: |
分类号: |
基金项目: |
|
Optimization of Determination of Butyl Xanthate by Copper Reagent Spectrophotometric Method |
NAN Shu qing1, DUO Ke xin1, ZHAO Xiu rong2, LUO Cai hong3
|
1.Henan Provincial Environmental Monitoring Center;2.Zhengzhou University;3.Chongqing Environmental Monitoring Center
|
Abstract: |
According to principle of the method, Optimization of method was approached by adjusting the sequence of reagent. After optimization, the stability of the reaction system is enhanced, with MDL 0.001mg/L. |
Key words: Butyl xanthate Copper reagent spectrophotometric method optimization |