引用本文:姜燕,王元有.淋洗液体系对碱片-离子色谱法测定硫酸盐化速率影响研究[J].环境监控与预警,2021,13(6):28-30
JIANG Yan, WANG Yuan-you.Study on the Influence of Eluent Liquid System on the Determination of Sulfation Rate by Alkaline Tablet Ion Chromatography[J].Environmental Monitoring and Forewarning,2021,13(6):28-30
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 3483次   下载 927 本文二维码信息
码上扫一扫!
分享到: 微信 更多
淋洗液体系对碱片-离子色谱法测定硫酸盐化速率影响研究
姜燕,王元有1,2
1.江苏省扬州环境监测中心, 江苏 扬州 225000;2. 扬州工业职业技术学院,江苏 扬州 225127
摘要:
分别用碳酸根淋洗液体系和氢氧根淋洗液体系碱片-离子色谱法对硫酸盐化速率样品进行比对试验。结果表明,2种淋洗液体系在0.00~20.0 mg/L质量浓度范围内线性良好,标准曲线相关系数均>0.999,检出限、精密度、准确度和测定结果都没有显著性差异,说明这2种淋洗液体系方法是等效的。采用氢氧根淋洗液体系分析硫酸盐化速率,可配备淋洗液发生器,背景更低,实验操作步骤更少,工作效率更高,建议作为首选方法。
关键词:  硫酸盐化速率  氢氧根体系  碳酸根体系  碱片-离子色谱法
DOI:
分类号:X831
基金项目:江苏省产学研项目基金资助项目(BY2020538);科技副总基金资助项目(FZ20200344);扬州市市校合作专项基金资助项目(YZ2018148,YZ2020171);扬州市自然科学基金资助项目(YZ2018099)
Study on the Influence of Eluent Liquid System on the Determination of Sulfation Rate by Alkaline Tablet Ion Chromatography
JIANG Yan, WANG Yuan-you1,2
1. Jiangsu Yangzhou Environmental Monitoring Center, Yangzhou, Jiangsu 225000,China;2.Yangzhou Polytechnic Institute,Yangzhou, Jiangsu 225127, China
Abstract:
The samples of sulfation rate were analyzed by ion chromatography with carbonate eluent system and hydroxyl eluent system respectively. The results showed that the two systems exhibited a good linearity in the range of 0.00~20.0 mg/L, and the correlation coefficient of the standard curve could reach 0.999, and there was no significant difference in the detection limit, precision, accuracy and determination results. Carbonate eluent system ion chromatography and hydroxyl eluent system ion chromatography are two equivalent methods. The hydroxyl eluent system is recommended to be the first choice to analyze the sulfation rate for the eluent generator can be equipped to lower background, fewer experimental operation steps and higher work efficiency.
Key words:  Sulfation rate  Hydroxyl system  Carbonate system  Alkaline Tablet Ion Chromatography